GEIL DLB-12 GAS KILN
GEIL Natural Draft Kilns
The frame construction and exterior shell of the GEIL Downdraft Gas Fired Fire Brick Kilns consists of heavy gauge structural strength steel. All frames are welded at each joint to provide for maximum strength and durability. Full width, front loading doors and the minimal area between the door opening and the setting space facilitates loading and unloading. These fire brick kilns are built with full depth arch construction extending directly to the door opening, providing stacking space to the top of the arch, 2600° F and 2800° F High Alumina (60% or more) Insulating Fire Brick backed by high-temperature block insulation constitutes the kiln's interior. All DL models will fire to 2500° F (cone 14).
Natural draft, high velocity ceramic burners were specifically designed and developed by GEIL Kilns to produce excellent fuel-air mixture without the need of electric blowers. These burners provide for simple and trouble-free firing.
STANDARD EQUIPMENT ON ALL GAS KILNS
|
|
-
Electronic flame safety, 100% shut off
-
Push button automatic spark ignition
-
Manual control valve
-
0-15" water column pressure gauge
-
DD-1 digital, solid state, electronic controller / high-limit, on/off soaking controller (see below)
DLB-12 SPECIFICATIONS
|
|
Model Number
|
DLB-12
|
|
Inside Volume -Cu.Ft.
|
17
|
|
Setting Space-Cu.Ft.
|
12
|
|
Setting Area-Inches
|
W D H 24x24x36
|
|
Inside Dimension-Inches
|
31x27x36
|
|
Outside Dimension-Inches
|
48x56x67
|
|
Instrumentation (Microprocessor Controller Optional Equipment)
|
DD1 Controller
|
|
Stacking Height-Inches
|
36
|
|
Temperature Range
|
0-2500� F.
|
|
Shelf Size-Inches Per Level
|
2-12x24
|
|
Maximum BTU/HR. Input
|
200,000
|
|
Maximum Gas Consumption CFH
|
180
|
|
Minimum Gas Pressure
|
6 Inches Water Column Pressure
|
|
Gas Line Inlet Inches
|
3/4"
|
|
Number of Burners
|
6
|
|
Average Firing Time-Cone 06
|
6 Hours
|
|
Average Firing Time-Cone 10
|
8-10 Hours
|
|
Approximate Shipping Weight
|
2,300 lbs.
|
|
|
Electrical hook-up required on all kilns. No extra charge for kilns firing with propane gas. Please specify.
STANDARD EQUIPMENT ON ALL GAS KILNS
|
|
-
Electronic flame safety, 100% shut off
-
Push button automatic spark ignition
-
Manual control valve
-
0-15" water column pressure gauge
-
DD-1 digital, solid state, electronic controller which functions as a high-limit, on/off soaking controller
|
|
|
|
Control System Standard manual control system used on most GEIL KILNS.
|
|
|
|
Control System Standard manual control system used on most GEIL Kilns.
|
|
|
|
DD-1 Digital Electronic ControllerThe DD-1 is a high limit, on-off, solid state electronic controller with a digital readout and digital set from 0 to 2500� F. When the controller is set at the "High Limit" position, it will automatically shut the kiln off at the set point temperature. The on-off position functions as a "soaking" controller, holding the temperature at the set point temperature, plus or minus 5�.
|
|
|
|
Heavy Duty Hinge An exclusive feature on all front loading GEIL Kilns, this hinge is fully greased to prevent rusting and reduce wear.
|
|
|
Burner System Natural draft, high velocity ceramic Venturi burners were specifically created and designed by GEIL Kiln Company for the GEIL Downdraft Design system and have proven to be quite efficient in all applications.
|
ALL GAS & ELECTRIC KILNS INCLUDE:
|
|
|
The ETL Certification All GEIL GAS KILNS conform to A.G.A. STANDARD 1-94 and certified to CSA STANDARD C22.2 NO.3.
All GEIL Electric kilns conform to UL STANDARD 1-94 and certified to CSA STANDARD C22.2 #221.
|
|
|
|